Biomedical sciences publications April 1, 2008

Fetal Thermal Effects of Diagnostic Ultrasound

Citation

Copy to clipboard


Abramowicz JS, Barnett SB, Duck FA, Edmonds PD, Hynynen KH, Ziskin MC. Fetal thermal effects of diagnostic ultrasound. J Ultrasound Med. 2008 Apr;27(4):541-59; quiz 560-3. doi: 10.7863/jum.2008.27.4.541. PMID: 18359908.

Abstract

Processes that can produce a biological effect with some degree of heating (ie, about 1 degrees C above the physiologic temperature) act via a thermal mechanism. Investigations with laboratory animals have documented that pulsed ultrasound can produce elevations of temperature and damage in biological tissues in vivo, particularly in the presence of bone (intracranial temperature elevation). Acoustic outputs used to induce these adverse bioeffects are within the diagnostic range, although exposure times are usually considerably longer than in clinical practice. Conditions present in early pregnancy, such as lack of perfusion, may favor bioeffects. Thermally induced teratogenesis has been shown in many animal studies, as well as several controlled human studies; however, human studies have not shown a causal relationship between diagnostic ultrasound exposure during pregnancy and adverse biological effects to the fetus. All human epidemiologic studies, however, were conducted with commercially available devices predating 1992, that is, with acoustic outputs not exceeding a spatial-peak temporal-average intensity of 94 mW/cm2. Current limits in the United States allow a spatial-peak temporal-average intensity of 720 mW/cm2 for fetal applications. The synergistic effect of a raised body temperature (febrile status) and ultrasound insonation has not been examined in depth. Available evidence, experimental or epidemiologic, is insufficient to conclude that there is a causal relationship between obstetric diagnostic ultrasound exposure and obvious adverse thermal effects to the fetus. However, very subtle effects cannot be ruled out and indicate a need for further research, although research in humans may be extremely difficult to realize.

↓ View online

Share this

How can we help?

Once you hit send…

We’ll match your inquiry to the person who can best help you.

Expect a response within 48 hours.

Career call to action image

Make your own mark.

Search jobs

Our work

Case studies

Publications

Timeline of innovation

Areas of expertise

Institute

Leadership

Press room

Media inquiries

Compliance

Careers

Job listings

Contact

SRI Ventures

Our locations

Headquarters

333 Ravenswood Ave
Menlo Park, CA 94025 USA

+1 (650) 859-2000

Subscribe to our newsletter


日本支社
SRI International
  • Contact us
  • Privacy Policy
  • Cookies
  • DMCA
  • Copyright © 2022 SRI International